loading...

picto

UrgoK2

Step-by-step application guide

close
I am:
Left-handed
The shape of the leg is:

Regular

Inverted champagne bottle

Fibrosis

Calf muscle wastage

Oedema

Leg type

Inverted champagne bottle

Venous hypertension can be associated with the formation of fibrin around the capillaries, with fibrosis and hardened skin in the gaiter area. This leads to a distorted leg shape.
We refer to inverted champagne bottle shape where the circumference of the upper calf is much bigger than that of the ankle

Leg type

Fibrosis of the ankle

Venous hypertension can be associated with the formation of fibrin around the capillaries, with fibrosis and hardened skin in the gaiter area. This leads to a distorted leg shape.

Leg type

Calf muscle wastage or areas at risk

Some areas (tibial crest, Achilles tendon, bone protusions…) are at risk of excess pressure, especially with patients presenting very thin legs or calf muscle wastage.

Leg type

Oedema

Venous hypertension can cause oedema as the fluid and waste metabolites are unable to be re-absorbed back into the venous system.

picto

UrgoK2

Step-by-step application guide

close

of

Shape the leg

Depending on leg morphology, fill the hollow, reconstitute the calf muscle or reinforce the ankle using a strip of wadding.
Modulate thickness according to the desired degree of reinforcement.
The goal is to recreate a "normal" leg shape.

pause play
plein ecran

Steps

Why shaping the leg?

Venous leg ulcer healing requires application of therapeutic compression, enabling the blood to rise from the bottom to the top of the body.

To enable blood to move up along the leg, compression should be degressive from the ankle (~40 mmHg) to the knee (~20 mmHg). For this, the patient’s leg should be shaped like an inverted cone. If this is not the case, a padding device (foam, wadding, cushions, etc.) may be used to re-form an inverted cone shape

of

Secure padding

Fasten the reinforcement with adhesive tape.

of

Shape the leg

Depending on leg morphology, fill the hollow, reconstitute the calf muscle or reinforce the ankle using a strip of wadding.
Modulate thickness according to the desired degree of reinforcement.
The goal is to recreate a "normal" leg shape.

Steps

Why shaping the leg?

Venous leg ulcer healing requires application of therapeutic compression, enabling the blood to rise from the bottom to the top of the body.

To enable blood to move up along the leg, compression should be degressive from the ankle (~40 mmHg) to the knee (~20 mmHg). For this, the patient’s leg should be shaped like an inverted cone. If this is not the case, a padding device (foam, wadding, cushions, etc.) may be used to re-form an inverted cone shape.

of

Secure padding

Fasten the reinforcement with adhesive tape.

of

Protect the leg

Cut a length of wadding strip.
Position it vertically along the tibial crest/zone.

Steps

Why protecting those areas? Which ones?

It is sometimes necessary to use padding devices (foam, wadding, cushions, etc.) to protect areas at risk of excess pressure (bone protrusions) to avoid possible lesions. These excess pressure areas are frequently located on the tibial crest, Achilles tendon, dorsum of the foot or other vulnerable tendons.

of

Measure the ankle

pause play
plein ecran

To choose the appropriate size, measure the ankle circumference, approximately 2 cm above the malleolus.

Steps

If the oedema is too big, you may need to palpate the leg to find the malleolus.

of

Measure the ankle

pause play
plein ecran

To choose the appropriate size, measure the ankle circumference after padding, approximately 2 cm above the malleolus.
Next, apply the system in a standard manner, above the reinforcement.

Steps

If the oedema is too big, you may need to palpate the leg to find the malleolus.

of

Measure the ankle

pause play
plein ecran

To choose the appropriate size, measure the ankle circumference after padding, approximately 2 cm above the malleolus.
Next, apply the system in a standard manner, above the reinforcement.

Steps

If the oedema is too big, you may need to palpate the leg to find the malleolus.

of

Measure the ankle

pause play
plein ecran

To choose the appropriate size, measure the ankle circumference after wadding, approximately 2 cm above the malleolus.
Next, apply the system in a standard manner, above the reinforcement.

Steps

If the oedema is too big, you may need to palpate the leg to find the malleolus

of

Measure the ankle

pause play
plein ecran

To choose the appropriate size, measure the ankle circumference, approximately 2 cm above the malleolus.

Steps

If the oedema is too big, you may need to palpate the leg to find the malleolus.

of

Select the white bandage

The UrgoK2 kit is composed of a short-stretch bandage (white - KTech) and a long-stretch (beige - KPress) bandage.

To start, pick up K-TECH, the white short-stretch bandage and open it.
The white bandage should be applied on the leg first, then the beige bandage will come on top.

of

Foot at 90° angle

pause play
plein ecran

Position the foot at a 90° angle

of

Foot at 90° angle

pause play
plein ecran

Position the foot at a 90° angle.

of

Apply on foot

pause play
plein ecran

Start at the base of the toes, making 1 to 2 wraps without applying excess pressure.
For the 18-25 cm kit, the pressure spot indicators should be towards the top of the leg.

of

Apply on foot

pause play
plein ecran

How to hold the bandage roll?
Apply the white bandage, positioning the roll upward (pressure spot indicators visible) and the pressure spot indicators towards the end of the toes.

Start at the base of the toes, making 1 to 2 wraps without applying excess pressure. For the 18-25 cm kit, the pressure spot indicators should be towards the toes.

of

Cover the heel with a figure 8

pause play
plein ecran

Take the heel, making a figure 8 wrap around the ankle. Ensure that the heel is fully covered.

of

Cover the heel with a figure 8

pause play
plein ecran

Take the heel, making a figure 8 wrap around the ankle. Ensure that the heel is fully covered.

of

The right stretch

pause play
plein ecran

To apply the correct tension, stretch the bandage fully and ensure that the oval becomes a circle.

Steps

The PresSure indicators should be pointing towards the bottom

of

The right stretch

pause play
plein ecran

To apply the correct tension, stretch the bandage fully and ensure that the oval becomes a circle.

of

The right overlap

pause play
plein ecran

To achieve the correct overlap, cover pressure indicators so that 50% of the previous wrap is covered for the 18-25cm kit, or 2/3 for the 25-32cm kit.

Steps

The PresSure indicators should be fully covered by the wraps

of

The right overlap

pause play
plein ecran

To achieve the correct overlap, overlap the wraps so that 50% of the previous wrap is covered for the 18-25cm kit, or 2/3 for the 25-32cm kit.
As you are left handed, the pressure spot indicators should remain visible.

of

Bandaging the leg

pause play
plein ecran

From the ankle, wrap up to the knee in spirals, using the pressure spot indicators as a guide for the level of stretch and overalap, as in the previous steps.

Steps

The PresSure indicators should be fully covered by the wraps

of

Bandaging the leg

pause play
plein ecran

From the ankle, wrap up to the knee in spirals, using the pressure spot indicators as a guide for the level of stretch and overalap, as in the previous steps

of

Stop below knee & cut excess bandage

pause play
plein ecran

Finish 2 cm below the knee and cut off any excess bandage.

Steps

Bandaging should stop at the 'Tibial Tuberosity’, ending at the back of the knee one or two fingers lower than the popliteal fossa.

of

Stop below knee & cut excess bandage

pause play
plein ecran

Finish 2 cm below the knee and cut off any excess bandage.

Steps

Bandaging should stop at the 'Tibial Tuberosity’, ending at the back of the knee one or two fingers lower than the popliteal fossa.

of

Secure with tape

pause play
plein ecran

Secure with adhesive tape

of

Secure with tape

pause play
plein ecran

Secure with adhesive tape

of

Where to start the 2nd bandage

pause play
plein ecran

To ensure that only the white bandage is in contact with the skin, leave a 1 cm margin around the toes.

of

Where to start the 2nd bandage

pause play
plein ecran

To ensure that only the white bandage is in contact with the skin, leave a 1 cm margin around the toes.

of

Apply the 2nd bandage

pause play
plein ecran

Apply the second bandage on top of the first, using the same technique.

Steps

To apply the correct tension, stretch the bandage fully and ensure that the oval becomes a circle.

To achieve the correct overlap, cover pressure indicators so that 50% of the previous wrap is covered for the 18-25cm kit, or 2/3 for the 25-32cm kit.

of

Apply the 2nd bandage

pause play
plein ecran

Apply the second bandage on top of the first, using the same technique.

Steps

To apply the correct tension, stretch the bandage fully and ensure that the oval becomes a circle.

To achieve the correct overlap, cover pressure indicators so that 50% of the previous wrap is covered for the 18-25cm kit, or 2/3 for the 25-32cm kit. The pressure spot indicators should remain visible.

of

Stop below knee

pause play
plein ecran

Here again, to ensure that only the white bandage is in contact with the skin, leave a 1 cm margin around the knee. Cut off any excess bandage.

of

Stop below knee

pause play
plein ecran

Here again, to ensure that only the white bandage is in contact with the skin, leave a 1 cm margin around the knee. Cut off any excess bandage.

of

Secure cohesion

pause play
plein ecran

Apply gentle pressure with the hands along the leg to ensure correct cohesion of the 2nd bandage

of

Secure cohesion

pause play
plein ecran

Apply gentle pressure with the hands along the leg to ensure correct cohesion of the 2nd bandage